2.4MW 420-Slot Antminer Hydro Cooling Container (40HQ)
$155,000.00 – $170,000.00Price range: $155,000.00 through $170,000.00
AP-HC40-A420 Plus hydro cooling system for up to 420 Antminer S19/S21/S23 hydro miners. Integrates racks, dual CDU controls, power distribution and PLC monitoring, with CE and UL versions available. The supplier lists 2,412 kW installed powerload.
Complete your order and payment first. Immediately after payment, visit our Order Customization page and submit the form with your customization requirements.
2.4MW 420-Slot Heavy-Duty Hydro Cooling Container for Megawatt Farms.
⚙ Compatible Models
View More ›293Th/s · 19 J/Th
420 SlotsFull-load: $4,695.60/day➜Antminer S21 XP Hydro473Th/s · 12 J/Th
420 SlotsFull-load: $7,581.00/day➜Antminer S21+ Hydro358Th/s · 15 J/Th
420 SlotsFull-load: $5,741.40/day➜Antminer S21e Hydro310Th/s · 17 J/Th
420 SlotsFull-load: $4,968.60/day➜Antminer S23 Hyd580Th/s · 9.5 J/Th
420 SlotsFull-load: $9,298.80/daySupplier reference estimates, not live or guaranteed earnings. Actual results vary with miner settings, network conditions, coin prices and electricity costs.
Product Description
The AP-HC40-A420 Plus is an integrated hydro cooling system for up to 420 Antminer hydro miners. A reinforced steel structure houses the racks, power distribution and cooling controls for megawatt-scale deployments.
Large-diameter stainless-steel manifolds and balanced CDU circulation distribute coolant across the mining racks. The integrated design is intended to reduce on-site installation work.
Core Advantages

01. Integrated All-in-One System
Racks, CDU, power cabinets and smart controls are integrated for simpler on-site setup.

02. Stainless Manifolds
Built-in seamless stainless manifolds and double-sealed quick connectors support compact plumbing and help reduce leakage.

03. Dual CDU Control Cabinets
Two independent control cabinets are paired with dual CDU systems for separate cooling control and maintenance access.

04. Dual 320L 4-in-1 Tanks
Two 320 L tanks combine gas separation, electrical heating, pressure stabilization and pump dry-run protection. The feature section states 87 m³/h pump flow; the specification table states 103 m³/h.

05. Power Distribution Cabinet
Industrial cabinets provide individual branch switches, status monitoring, overcurrent and short-circuit protection, and maintenance isolation.

06. PLC Intelligent Control System
PLC and HMI controls monitor pumps, cooling fans, water temperature, pressure and flow.
Full Specifications
| Model | AP-HC40-A420 Plus |
|---|---|
| Installed capacity | 420 seats |
| External dimensions (L × W × H) | 12192 × 2438 × 2896 mm |
| Internal dimensions (L × W × H) | 12000 × 2230 × 2660 mm |
| Weight | 9080 kg |
| Installed powerload | 2412 kW |
| System composition | Dry cooler container × 1; device container × 1 (PDC × 2 + RACK × 2 + CDU) |
| System energy consumption | 108 kW |
| Heat dissipation capacity | >2000 kW |
| Pump | 11 kW × 2 |
| Control system | PLC control console |
| CDU | All-in-one water tank; pump: 103 m³/h |
| PDC | Main breaker: 3200 A (1600 A × 2); miner breakers: 16 A × 210 pcs |
| NET Switch | 24 ports; 1000 Mbps × 14 pcs |
| Environmental adaptability | −20°C to 45°C |
| Input | Three-phase 380–415V, 60Hz/50Hz |
| Supplier-listed certification | CCS, CE, UL |
The supplier overview shows 2,400 kW, the detailed table lists 2,412 kW, and its FAQ refers to 2,310 kW. Pump flow is listed as 87 m³/h in the feature section and 103 m³/h in the table. Confirm the final rated load, pump duty and cooling capacity for the order.
Certification Standards
The supplier states that its products meet leading international standards for safety, reliability, and performance.

China Classification Society
Marine & offshore compliance

UL Listed
Safety tested & certified

CSA Certified
North American compliance

CE Marking
European conformity
Complete Cooling Solutions
Supplier-listed Antminer hydro cooling options for different deployment sizes.
| Model | ❄️ Cooling Capacity | ⚙️ Miner Slots | 📏 Dimensions (L × W × H) | 🏢 Application |
|---|---|---|---|---|
| 308-Slot Antminer Hydro Cooling Container | 1.7 MW | 308 Slots | 12,192 × 2,438 × 2,896 mm | Standard Industrial Operations |
| 364-Slot Antminer Hydro Cooling Container | 2.1 MW | 364 Slots | 12,192 × 2,438 × 2,896 mm | High-Density Mining Farms |
| 420-Slot Antminer Hydro Cooling Container | 2.4 MW | 420 Slots | 12,192 × 2,438 × 2,896 mm | Mega-Scale Utility Projects |
| 480-Slot Antminer Hydro Cooling Container | 2.6 MW | 480 Slots | 12,192 × 2,438 × 2,896 mm | Enterprise-Class Global Facilities |
Real Results from Real Miners
Supplier-reported projects and performance figures. These are supplier claims, not independently verified results or MiningUS customer testimonials.

Atlanta, United States
12 × 2.4MW Hydro Project
Reducing on-site installation costs through pre-wired containers.
+32% Cooling Efficiency
-30% Deployment Time
$1.5M Annual Savings

Luleå, Sweden
8 × 2.4MW Hydro Project
Improving deployment efficiency with stackable dry coolers.
+100% Operational Uptime
-40% Shipping Space
99.9% System Reliability
Supplier global deployment figures: 1.2+ GW cumulative delivered cooling capacity across 50+ countries and regions.
420-Slot Antminer Hydro Cooling Container FAQs
How much make-up water is required?
The supplier FAQ gives conflicting figures: 58 tonnes per day for the system and 0.004 tonnes per miner per day, which do not agree for 420 miners. It also refers to 2.31 MW instead of the table’s 2.412 MW. Confirm water demand for the selected cooling configuration and site conditions.
How are pressure and flow balanced?
The supplier describes equal-length piping and a 0.2–0.4 MPa operating pressure to distribute coolant across the racks.
What dry cooler design is supplied?
The supplier describes variable-speed fans, stainless-steel coils and corrosion-resistant coated fins. Confirm the final cooler specification and thermal duty for the site.
Can the electrical system be customized?
The detailed specification lists three-phase 380–415V at 50/60Hz. Confirm the ordered electrical configuration and regional certification requirements.
What data can the control system monitor?
The supplier describes real-time voltage, loop-pressure and temperature curves, leak detection, fault alarms, multilingual parameter settings and OTA upgrades. Its FAQ describes a 22–42°C system operating range; the table gives −20°C to 45°C environmental adaptability.
| Specification | CE Version, UL Version |
|---|
Delivery costs shown before payment
Enter your complete delivery address at checkout to see available shipping services and charges. Shipping is separate from the product price unless expressly included. A missing rate does not mean free delivery.
Miners and spare parts
Confirmed in-stock items generally need 3–7 business days for preparation after cleared payment. Express transit is typically estimated at 5–10 business days after collection; the selected service and destination determine the actual estimate.
Cooling systems and heavy equipment
Containers, tanks, racks and other oversized equipment travel by suitable freight services. Delivery point, site access and unloading requirements must be confirmed. If no freight option is available at checkout, contact us before payment.
Customs and delivery support
Import duty, import taxes and brokerage are excluded unless the order explicitly confirms DDP or another duty-inclusive service. Tracking or waybill details are provided after dispatch. Inspect your delivery and contact us promptly about damage or missing items; an unboxing video is helpful but is not required for support.
Read the full shipping policy | Contact Mining US
Dispatch and transit estimates are separate and may be affected by customs, carrier disruption or public holidays. Applicable consumer rights remain unaffected.

Reviews
There are no reviews yet.