2.4MW 240-Slot Whatsminer 2U Hydro Cooling Container (40HQ)
$130,000.00 – $182,000.00Price range: $130,000.00 through $182,000.00
AP-HC40-M240 hydro cooling container with 2.4 MW installed power capacity and space for up to 240 Whatsminer 2U hydro miners. Includes rack cabinets, individual slot protection and a CDU with automatic fluid replenishment.
Complete your order and payment first. Immediately after payment, visit our Order Customization page and submit the form with your customization requirements.
2.4MW 240-Slot Whatsminer 2U Hydro Cooling Container for Enterprise Mining
⚙ Compatible Models
View More ›320Th/s · 22 J/Th
240 SlotsFull-load: $2,947.20/day➜Whatsminer M63S390Th/s · 18.5 J/Th
240 SlotsFull-load: $3,592.80/day➜WhatsMiner M73526TH/s · 14.5 J/Th
240 SlotsFull-load: $4,845.60/day➜WhatsMiner M73S552TH/s · 13.5 J/Th
240 SlotsFull-load: $5,085.60/day➜WhatsMiner M73S+600TH/s · 12.5 J/Th
240 SlotsFull-load: $5,527.20/daySupplier reference estimates, not live or guaranteed earnings. Actual results vary with miner settings, network conditions, coin prices and electricity costs.
Product Description
The AP-HC40-M240 is a 2.4 MW hydro cooling container designed for up to 240 Whatsminer 2U hydro miners. The supplier describes a C-class datacenter layout with metal partitions separating hot and cold aisles.
Water pipes and electrical cabling are physically separated. A gas fire-suppression system at the entrance and automatic reclosing breakers support operational protection.
Core Advantages

01. Datacenter-Style Layout
Structured rack cabinet groups with individual doors support maintenance access and hot/cold aisle separation.

02. Advanced CDU System
The CDU combines water pumps, a bottom pressure tank and an automatic refill pipe for fluid replenishment and pressure management.

03. Individual Control Switches
Each rack slot has an individual power switch and breaker with matching labels for targeted maintenance.

04. Electric Leakage Protection
Auto-reclosing breakers, residual-current protection and lightning arrestors provide electrical protection.

05. Power Distribution Cabinet
Power cabinets use automatic reclosing breakers and hand-operated side screws for routine service access.

06. Water & Electricity Isolation
Power cabinets and liquid manifolds are positioned on opposite sides of the aisle to separate electrical and water systems.
Full Specifications
| Model | AP-HC40-M240 |
|---|---|
| Installed capacity | 240 seats |
| External dimensions (L × W × H) | 13716 × 2438 × 2896 mm |
| Internal dimensions (L × W × H) | 13500 × 2230 × 2660 mm |
| Weight | 7800 kg |
| Installed powerload | 2400 kW |
| Light-duty vertical multistage pump power | 30 kW |
| Fluid replenishing pump power | 0.2 kW |
| Total dry cooling tower fan power | 58.1 kW |
| Total closed cooling tower fan power | 22.5 kW |
| Total closed cooling tower spray pump power | 7.5 kW |
| System pipeline pressure | 0.2–0.4 MPa |
| System operating temperature range | 0–50°C |
| Coolant circulation demand per machine | ≥0.6 m³/h |
| Total circulating coolant demand | ≥2.5 m³ |
| Molded Case Circuit Breaker | 125 A |
| Residual Current Circuit Breaker | 400 A |
| Contactor | 9 A |
| Intermediate relay | 24 V |
| CUL certified frequency converter | 380 V |
The source title describes 40HQ, while its table lists a 13,716 mm external length. Confirm final dimensions before planning the site or freight.
Certification Standards
The supplier states that its products meet leading international standards for safety, reliability, and performance.

China Classification Society
Marine & offshore compliance

UL Listed
Safety tested & certified

CSA Certified
North American compliance

CE Marking
European conformity
Complete Cooling Solutions
Supplier-listed hydro cooling container options for different deployment sizes.
| Model | ❄️ Cooling Capacity | ⚙️ Miner Slots | 📏 Dimensions (L × W × H) | 🏢 Application |
|---|---|---|---|---|
| 100-Slot Whatsminer Hydro Cooling Container | 1 MW | 100 Slots | 6058 × 2438 × 2896 mm | Compact Mining Sites |
| 120-Slot Whatsminer Hydro Container | 1.2 MW | 120 Slots | 6058 × 2438 × 2896 mm | Commercial-Scale Mining |
| 160-Slot Whatsminer Hydro Container | 1.6 MW | 160 Slots | 6058 × 2438 × 2896 mm | Industrial-Scale Operations |
| 240-Slot Whatsminer Hydro Container | 2.4 MW | 240 Slots | 13716 × 2438 × 2896 mm | Mega-Scale Mining Facilities |
Real Results from Real Miners
Supplier-reported projects and performance figures. These are supplier claims, not independently verified results or MiningUS customer testimonials.

Tashkent, Uzbekistan
10 × 2.4MW Hydro Project
Sustaining stable high-yield operations under industrial grids.
+32% Hashrate Stability
-25% Cooling Power Draw
$1.8M Annual Savings

Austin, United States
6 × 2.4MW Hydro Project
Defeating extreme Texas summer heat with advanced liquid cooling.
+100% Operational Uptime
-30% Setup Time
99.9% System Reliability
Supplier global deployment figures: 1.2+ GW cumulative delivered cooling capacity across 50+ countries and regions.
240-Slot Whatsminer Hydro Cooling Container FAQs
Which Whatsminer models are compatible?
The supplier lists Whatsminer 2U hydro models M53, M53S, M63, M63S, M6D, M7D and M73 series, with capacity for up to 240 units. Confirm the exact miner configuration for your order.
How is the 2.4 MW electrical load distributed?
Industrial power cabinets and copper busbars distribute power through individual breakers for the rack positions.
What backup does the cooling system provide?
The supplier describes a redundant dual-pump CDU with automatic failover in its FAQ. The specification table lists 30 kW pump power without a pump quantity; confirm the supplied pump arrangement.
How is water flow balanced?
Stainless-steel manifolds are designed to maintain balanced flow and pressure across the miners.
What should be confirmed for transport?
The supplier markets the unit as 40HQ and describes CSC-standard transport, but lists a 13,716 mm external length. Confirm the actual shipping dimensions and certification documents before arranging freight.
| Specification | CE Version-2.4MW-240Rigs, UL Version-2.4MW-240Rigs |
|---|
Delivery costs shown before payment
Enter your complete delivery address at checkout to see available shipping services and charges. Shipping is separate from the product price unless expressly included. A missing rate does not mean free delivery.
Miners and spare parts
Confirmed in-stock items generally need 3–7 business days for preparation after cleared payment. Express transit is typically estimated at 5–10 business days after collection; the selected service and destination determine the actual estimate.
Cooling systems and heavy equipment
Containers, tanks, racks and other oversized equipment travel by suitable freight services. Delivery point, site access and unloading requirements must be confirmed. If no freight option is available at checkout, contact us before payment.
Customs and delivery support
Import duty, import taxes and brokerage are excluded unless the order explicitly confirms DDP or another duty-inclusive service. Tracking or waybill details are provided after dispatch. Inspect your delivery and contact us promptly about damage or missing items; an unboxing video is helpful but is not required for support.
Read the full shipping policy | Contact Mining US
Dispatch and transit estimates are separate and may be affected by customs, carrier disruption or public holidays. Applicable consumer rights remain unaffected.

Reviews
There are no reviews yet.