1.2MW 120-Slot Whatsminer 2U Hydro Cooling Container (20HQ)
1.2MW 120-Slot Whatsminer 2U Hydro Cooling Container (20HQ) Price range: $65,000.00 through $103,000.00
Back to products
AP-HC40-M240 2.4 MW 240-slot Whatsminer hydro cooling container
2.4MW 240-Slot Whatsminer 2U Hydro Cooling Container (40HQ) Price range: $130,000.00 through $182,000.00

1.6MW 160-Slot Whatsminer 2U Hydro Cooling Container (20HQ)

Price range: $79,000.00 through $115,000.00

This 20ft hydro mining container supports 160 Whatsminer or Avalon 2U hydro rigs, also compatible with 104 Antminer 3U rigs for efficient hydro cooling, delivering 1.6MW capacity.

Need Customization?

Complete your order and payment first. Immediately after payment, visit our Order Customization page and submit the form with your customization requirements.

Description

160-Slot High-Density Hydro Cooling Container for Whatsminer 2U Series

Container Capacity
ASIC Miners
160 UNITS
Housed at full load
Total Power
1,600 KW
Continuous electrical load
Form Factor
Custom
Standard
Cooling
Hydro
Thermal management
Power Input 380V–415V AC 50/60Hz
Availability Typical lead time 45 days • DDP Sea Shipping Available

⚙ Compatible Models

View More ›
Whatsminer M53S++
320Th/s · 22 J/Th
160 Slots Full-load: $1,598.40/day
→
Whatsminer M63S
390Th/s · 18.5 J/Th
160 Slots Full-load: $1,948.80/day
→
WhatsMiner M73
526Th/s · 14.5 J/Th
160 Slots Full-load: $2,627.20/day
→
WhatsMiner M73S
552Th/s · 13.5 J/Th
160 Slots Full-load: $2,758.40/day
→
WhatsMiner M73S+
600Th/s · 12.5 J/Th
160 Slots Full-load: $2,998.40/day
→

Product Description

 

Optimized for high density configurations, the 1.6MW 160-Slot Whatsminer 2U Hydro Cooling Container 20FT HQ maximizes physical space utilization.

Built to pack 160 Whatsminer 2U hydro servers into the same compact 20 foot frame, this scalable infrastructure manages a heavy 1600kW thermal load. It utilizes engineered high flow stainless steel manifolds and robust CDU circulation to guarantee uniform water pressure across all highly compressed server rows under continuous full load operations.

Ideal for footprint constrained sites seeking maximum hashing output and capital return, this highly integrated, space saving water cooling container minimizes total onsite land overhead while securing highly consistent thermal cooling performance globally.

⌘

Core Advantages

01. Integrated All-in-One System

Integrates the server racks, CDU, power cabinet, and control unit into a single 20FT container for rapid on-site setup, minimizing civil engineering costs and deployment time.

02. Advanced CDU System

The CDU system manages critical heat exchange between the internal and external coolant loops, continuously regulating flow, stabilizing loop pressure, and optimizing overall thermal efficiency.

03. Redundant Dual-Loop Cooling

Engineered with redundant circulation architecture to improve cooling reliability across the full rack. Clearly separated supply and return paths help maintain balanced coolant flow during continuous high-density mining.

04. Individual Power Switches

Every miner slot is equipped with an independent breaker, allowing safe maintenance or replacement of a single unit without interrupting the operation of the remaining miners.

05. Instant Leak Detection

High-sensitivity floor-mounted moisture-sensing ropes detect coolant leakage quickly and can trigger immediate alarms, helping operators respond before valuable mining equipment is affected.

06. Standard 2U Server Racking

Purpose-built 2U server racks are matched for compatible WhatsMiner hydro models, providing organized installation, convenient access, and simplified miner replacement and maintenance.

▦

Full Specifications

External dimensions
L:6058mm、W:2438mm、H:2896mm
Internal dimensions
L:5860mm、W:2348mm、H:2720mm
Weight
4500KG
Model AP-HC20-M160 Installed capacity 160 Seat
Installed powerload 1600 kW Power of the light-duty vertical multistage pump 30 kW
Power of the fluid replenishing pump 0.2 kW Total power of the dry cooling tower fan 41.5 kW
Total power of the closed cooling tower fan 17.6 kW Total power of the closed cooling tower spray pump 4 kW
System pipeline pressure 0.2–0.4 MPa Operating temperature range of the system 0–50 °C
Coolant circulation demand of a single machine ≥0.6 m³/h Total demand for circulating coolant within the system ≥1.7 m³
Molded Case Circuit Breaker 125 A Residual Current Circuit Breaker 400 A
Contactor 9 A Intermediate relay 24 V
CUL certified frequency converter 380 V

Certification Standards

Our products meet leading international standards for safety, reliability, and performance.

China Classification Society
China Classification Society
Marine & offshore compliance
UL Listed
UL Listed
Safety tested & certified
CSA Certified
CSA Certified
North American compliance
CE Marking
CE Marking
European conformity

Complete Cooling Solutions

We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.

100-Slot Whatsminer Hydro Container
120-Slot Whatsminer Hydro Container
Compare
160-Slot Whatsminer Hydro Container
240-Slot Whatsminer Hydro Container
❄ Cooling Capacity 1 MW 1.2 MW 1.6 MW 2.4 MW
⚙ Miner Slots 100 Slots 120 Slots 160 Slots 240 Slots
📏 Dimensions (L × W × H) 6,058 × 2,438 × 2,896 mm 6,058 × 2,438 × 2,896 mm 6,058 × 2,438 × 2,896 mm 13,716 × 2,438 × 2,896 mm
▣ Application Entry-Level Mining Sites Commercial-Scale Operations Industrial-Scale Projects Mega-Scale Mining Facilities

Real Results from Real Miners

View All ››
Ciudad del Este, Paraguay

7 × 1.6MW Hydro Project

Sustaining highly stable, high-yield mining operations under demanding humid tropical climate conditions.

+32% Space Optimization
-25% Cooling Power Draw
$1.1M Annual Savings
Irkutsk, Russia

8 × 1.6MW Hydro Project

Maintaining highly consistent thermal dissipation across harsh winter seasons and high-density mining loads.

+100% Operational Uptime
99.8% System Reliability
120W USD Energy Cost
“

Squeezing 1.6MW into a 20FT container gave us substantial space savings. The pre-wired setup allowed our Siberian team to go online quickly, ensuring highly reliable, consistent winter hashing.

— O&M Director,
Irkutsk Mining Facility, Russia
Global Deployment
1.2+ GW
Cumulative delivered cooling capacity
Serving Mining Sites
50+
Countries and regions covered

160-Slot Whatsminer Hydro Cooling Container FAQs

This 1.6MW-class container is custom engineered for MicroBT standard 2U hydro servers, supporting compatible WhatsMiner M53, M63, M73, M6d, and M7d series models with matching internal cabinet rack dimensions and hydro interfaces.

To handle the intense 1.6MW thermal load inside a compact 20FT container, the system uses large-diameter coolant manifolds, high-capacity circulation pumps, and robust CDUs.

This helps maintain consistent pressure and balanced coolant flow across all 160 miner positions, reducing uneven thermal loading and minimizing localized hot spots.

Engineered for heavy-duty industrial electrical grids, this container can be integrated with a suitably sized industrial transformer, such as a 2000kVA-class system depending on the site's final electrical design.

The site should provide sufficient three-phase electrical capacity for the miner load plus cooling-system auxiliary equipment, with appropriate upstream protection, grounding, cabling, and distribution equipment.

The container shell uses a multi-layer protective coating process to improve corrosion resistance during long-term outdoor operation.

The internal structure also incorporates thermal and fire-resistant insulation materials, helping stabilize internal operating conditions under high ambient temperatures while improving overall structural protection.

Yes. The intelligent control backend monitors key operating parameters and can trigger alarms when abnormal equipment conditions are detected.

Monitoring can cover circulation pumps, temperature, pressure, coolant flow, leak detection, fans, and sensor status, helping operators identify abnormal sections quickly and reduce troubleshooting time.

Additional information
SpecificationCE Version-1.6MW-160Rigs, UL Version-1.6MW 160Rigs
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “1.6MW 160-Slot Whatsminer 2U Hydro Cooling Container (20HQ)”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

Delivery costs shown before payment

Enter your complete delivery address at checkout to see available shipping services and charges. Shipping is separate from the product price unless expressly included. A missing rate does not mean free delivery.

Miners and spare parts

Confirmed in-stock items generally need 3–7 business days for preparation after cleared payment. Express transit is typically estimated at 5–10 business days after collection; the selected service and destination determine the actual estimate.

Cooling systems and heavy equipment

Containers, tanks, racks and other oversized equipment travel by suitable freight services. Delivery point, site access and unloading requirements must be confirmed. If no freight option is available at checkout, contact us before payment.

Customs and delivery support

Import duty, import taxes and brokerage are excluded unless the order explicitly confirms DDP or another duty-inclusive service. Tracking or waybill details are provided after dispatch. Inspect your delivery and contact us promptly about damage or missing items; an unboxing video is helpful but is not required for support.

Read the full shipping policy  |  Contact Mining US

Dispatch and transit estimates are separate and may be affected by customs, carrier disruption or public holidays. Applicable consumer rights remain unaffected.