AP-HC40-A420 Plus 2.4 MW hydro cooling container with stacked dry cooler
2.4MW 420-Slot Antminer Hydro Cooling Container (40HQ) Price range: $155,000.00 through $170,000.00
Back to products
1.2MW 120-Slot Whatsminer 2U Hydro Cooling Container (20HQ)
1.2MW 120-Slot Whatsminer 2U Hydro Cooling Container (20HQ) Price range: $65,000.00 through $103,000.00

2.64MW 480-Slot Antminer Hydro Cooling Container (40HQ)

Price range: $114,600.00 through $167,500.00

AP-HC40-A480 hydro cooling container with 2.64MW installed capacity and space for up to 480 Antminer hydro miners. Choose a closed cooling tower or dry cooler solution for your site.

Need Customization?

Complete your order and payment first. Immediately after payment, visit our Order Customization page and submit the form with your customization requirements.

Description

2.64MW 480-Slot Ultra-Density Hydro Cooling Container for BTC Mining

Container capacity
ASIC miners
480 UNITS
Housed at full load
Total power
2,640 kW
Continuous electrical load
Form factor
Custom
Standard
Cooling
Hydro
Thermal management
Power input380V–415V AC 50/60Hz
AvailabilityTypical lead time 45 days • DDP Sea Shipping Available

⚙ Compatible Models

View More ›

Supplier reference estimates, not live or guaranteed earnings. Actual results vary with miner settings, network conditions, coin prices and electricity costs.

Product Description

The AP-HC40-A480 integrates capacity for up to 480 Antminer hydro miners into a 40HQ container with a listed 2.64MW installed power load. It is designed for large industrial mining sites, utility-scale deployments and sites using off-grid power stations.

Integrated racks, cooling distribution, power cabinets and controls simplify installation while supporting high-density operation.

Core Advantages

AP-HC40-A480 Integrated All-in-One System

01. Integrated All-in-One System

Server racks, CDU, power cabinets and smart controls are integrated in a single 40FT container to simplify setup and reduce on-site construction.

AP-HC40-A480 Redundant Dual-Loop Cooling

02. Redundant Dual-Loop Cooling

Separate water circulation loops and dual pumps support continued cooling when one side loses power.

AP-HC40-A480 Individual Power Switches

03. Individual Power Switches

Four power cabinets, two at the front and two at the back, distribute the 2.64MW electrical load.

AP-HC40-A480 Leak Detection System

04. Leak Detection System

Floor-mounted moisture-sensing ropes detect coolant leaks and trigger remote alarms and automatic power cutoffs.

AP-HC40-A480 Excellence Roots in Details

05. Excellence Roots in Details

Aviation plugs and double-sealed quick connectors simplify connections and help reduce leakage during maintenance.

AP-HC40-A480 Intelligent Management System

06. Intelligent Management System

Smart controls monitor flow, pressure, temperature and PUE, with automatic regulation and remote access from mobile or PC.

Full Specifications

ModelAP-HC40-A480
Installed capacity480 miners
Installed power load2,640 kW
External dimensions (L × W × H)12,192 × 2,438 × 2,896 mm
Internal dimensions (L × W × H)12,000 × 2,230 × 2,660 mm
Weight9,200 kg
Power input380–415V AC, 50/60Hz
Light-duty vertical multistage pump30 kW
Fluid replenishing pump0.2 kW
Dry cooling tower fan total power116.2 kW
Closed cooling tower fan total power35.2 kW
Closed cooling tower spray pump total power11 kW
System pipeline pressure0.2–0.4 MPa
System operating temperature22–42°C
Coolant circulation demand per miner≥0.5 m³/h
Total circulating coolant demand≥6 m³
Molded case circuit breaker250 A
Residual current circuit breaker800 A
Contactor9 A
Intermediate relay24 V
CUL-certified frequency converter380 V

Certification Standards

The supplier states that its products meet leading international standards for safety, reliability, and performance.

China Classification Society

China Classification Society

Marine & offshore compliance

UL Listed

UL Listed

Safety tested & certified

CSA Certified

CSA Certified

North American compliance

CE Marking

CE Marking

European conformity

Complete Cooling Solutions

Supplier-listed Antminer hydro cooling options for different deployment sizes.

Model❄️ Cooling Capacity⚙️ Miner Slots📏 Dimensions (L × W × H)🏢 Application
308-Slot Antminer Hydro Cooling Container1.7 MW308 Slots12,192 × 2,438 × 2,896 mmStandard Industrial Operations
364-Slot Antminer Hydro Cooling Container2.1 MW364 Slots12,192 × 2,438 × 2,896 mmHigh-Density Mining Farms
420-Slot Antminer Hydro Cooling Container2.4 MW420 Slots12,192 × 2,438 × 2,896 mmMega-Scale Utility Projects
480-Slot Antminer Hydro Cooling Container2.6 MW480 Slots12,192 × 2,438 × 2,896 mmEnterprise-Class Global Facilities

Real Results from Real Miners

Supplier-reported projects and performance figures. These are supplier claims, not independently verified results or MiningUS customer testimonials.

Supplier container transported on a truck

Monterrey, Mexico

12 × 2.64MW Hydro Project

Large-scale modular deployment under continuous industrial power.

+30% Space Optimization
-23% Capex Saved
$1.6M Annual Savings

Supplier hydro cooling deployment in snowy conditions

Ekibastuz, Kazakhstan

10 × 2.64MW Hydro Project

Large-scale mining operations under heavy thermal load.

+100% Operational Uptime
-30% Setup Time
99.9% System Reliability

Supplier global deployment figures: 1.2+ GW cumulative delivered cooling capacity across 50+ countries and regions.

480-Slot Antminer Hydro Cooling Container FAQs

Does the dry cooler need water replenishment?

The supplier describes a closed-loop dry cooler with no evaporative water consumption. For cold regions it recommends an appropriate ethylene-glycol mixture to protect pipework from freezing. This describes the dry cooler option.

How does the dry cooler handle high ambient temperatures?

High-power fans, large piping and fluid-guiding tubes improve heat dissipation. Confirm full-load cooling performance for the actual site temperature and miner configuration.

Can the electrical system be customized?

The supplier offers regional electrical configurations, including European three-phase and North American 60Hz systems. The standard listed input is 380–415V AC, 50/60Hz.

What materials are used in the dry cooler?

The supplier lists stainless-steel coils and hydrophilic aluminum fins with anti-corrosion coatings, and states a ten-year design lifespan. This is a supplier statement, not a warranty term.

What is the lead time and shipping method?

The overview lists a typical 45-day lead time, while the FAQ states four to six weeks. Confirm the schedule for the selected configuration. The ISO-sized container supports standard international sea and rail transport.

Additional information
SpecificationClosed Cooling Tower Solution, Dry Cooler Solution
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “2.64MW 480-Slot Antminer Hydro Cooling Container (40HQ)”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

Delivery costs shown before payment

Enter your complete delivery address at checkout to see available shipping services and charges. Shipping is separate from the product price unless expressly included. A missing rate does not mean free delivery.

Miners and spare parts

Confirmed in-stock items generally need 3–7 business days for preparation after cleared payment. Express transit is typically estimated at 5–10 business days after collection; the selected service and destination determine the actual estimate.

Cooling systems and heavy equipment

Containers, tanks, racks and other oversized equipment travel by suitable freight services. Delivery point, site access and unloading requirements must be confirmed. If no freight option is available at checkout, contact us before payment.

Customs and delivery support

Import duty, import taxes and brokerage are excluded unless the order explicitly confirms DDP or another duty-inclusive service. Tracking or waybill details are provided after dispatch. Inspect your delivery and contact us promptly about damage or missing items; an unboxing video is helpful but is not required for support.

Read the full shipping policy  |  Contact Mining US

Dispatch and transit estimates are separate and may be affected by customs, carrier disruption or public holidays. Applicable consumer rights remain unaffected.