96-Slot Natural Gas Generator Hydro Cooling Container for Antminer Hydro
$185,000.00
✓ 1 Year Warranty
AP-50Hyd container with two 250kW natural-gas generators, 96 Antminer Hydro mining slots, integrated networking and ventilation, and two micro-channel dry coolers. Combined continuous generator output: 500kW.
AP-50Hyd: Natural Gas-Powered Water-Cooled Mining Solution
The AP-50Hyd combines two 250kW natural-gas generator modules with 96 Antminer Hydro mining slots, integrated networking, ventilation and micro-channel dry coolers. The modular installation combines on-site generation and liquid cooling for mining deployments.
| Number of machines | 96 |
|---|---|
| Continuous Power | 250kW x 2 |
| Standby Power | 300kW x 2 |
| Frequency | 50/60 Hz |
| Voltage | 400V/480V |
| Fuel | Natural Gas / Associated Gas / Coal Mine Gas / Biogas |

Key Features
- Two AP-25 250kW generator modules provide 500kW combined continuous power.
- 96 hydro miner positions with integrated power distribution and networking.
- Two micro-channel dry coolers; the supplier overview describes 500kW thermal capacity.
- 40HQ modular enclosure for deployment and expansion.

Specifications
Supplier specification differences: The overview lists standby power at 300kW × 2, while its graphic says emergency power 250kW × 2. Cooling is stated as 500kW in the overview and 550kW in the detailed table. The 630kW maximum load is a separate equipment rating, not the 500kW continuous generator output. Confirm the final configuration and operating conditions before site design.
AP-50Hyd Container
| Size | 12192*2438*2896(L*W*Hmm,±5mm) |
|---|---|
| Rack | 8 Rows and 12 Columns Per Group |
| Input Voltage | Three-phase 380-480V 50/60Hz |
| Continuous power | 500kW total from overview; detailed supplier row incorrectly repeats a voltage |
| Max Power Load | 630 kW |
| Ambient Temperature | -25°C~35°C |
| Capacity | 96units Antminer Hydro Miners(Support Customization) |
| Network | 5*100M 24*bps Ethernet Switch |
| Cooling System | Hydro Cooling |
| Inlet and Outlet Temp | 50/60°C |
| Input Voltage | Three-phase 350-480V 50/60Hz |
| Output Voltage | Three-phase 350-480V 50/60Hz |
| Certification | ETL (supplier statement) |
| Cooling Capacity | 550kW (-30°-45°) |
| Input Voltage | Three-phase 350-480V 50Hz/60Hz |
| Power Consumption | 3kW *6 |
| Noise | <99dB(A)@10m |
The source lists 380–480V input in one row and 350–480V in other rows, plus different temperature ranges for the container and cooler. Network notation is reproduced as supplied; verify port counts and link speed for the final build.
Generator Set
| Engine Brand | Geely |
|---|---|
| Engine Model | AP-25 |
| Number of Cylinders | 6 |
| Bore/Stroke | 129×165 mm |
| Displacement | 12.94 L |
| Compression Ratio | 10.5:1 |
| Rated Speed | 1500/1800 r/min |
| Intake Type | Turbocharged and Intercooled |
| Cooling Method | Closed-loop forced water cooling |
| Lubrication Method | Pressurized and splash lubrication |
| Oil Pressure | 2.5 bar–5.8 bar |
| Oil Temperature | ≤105°C |
| Oil Capacity | 32 L |
| Firing Order | 1-5-3-6-2-4 |
| Crankshaft Rotation | Counterclockwise |
| Fuel Intake Pressure | 5 kPa |
Engine and Electrical System
| Brand | Geely |
|---|---|
| Model | HMT13F.408 30 |
| Continuous Power | 250KW |
| Rated Current | 450A |
| Rated Frequency | 50/60Hz |
| Power Factor | 0.8 |
| Starting Method | DC 24V Electric Start |
| Speed Control Method | Electronic Speed Control |
| Fuel Control Method | Lean Burn, Closed-Loop Control |
| Ignition Method | High-Voltage Spark Plug Ignition |
| Generator Set Operation Mode | One-Key Auto Start |
| Oil Consumption Rate | ≤0.3g/kWh |
| Noise | 10 meters ≤ 101 dB(A) |
| NOx Emissions | 1.347g/kWh |
| Electrical Efficiency | 35% |
| Thermal Efficiency | 47% |
| Electrical certification | ETL (supplier statement) |
| Generator Set Dimensions | 3100X1330X1590mm |
| Generator Set Weight | 3140kg |
| Number of Phases and Connection Method | Three-Phase Four-Wire, Star Connection |
| Cooling Method | Pen-type Circulating Forced Water Cooling |
| Air Source Inlet Pressure | 0.4Mpa |
| Air Source Outlet Pressure | 5-10Kpa |
Supplier Deployment Examples
Project photographs and figures shown on the supplier’s page. These are supplier examples, not independently verified MiningUS customer installations.
Canadian project
20 devices · 5MW · Natural gas
LNG power station project
14 devices · 3.5MW · Landfill gas, as labeled by the supplier
Canada project
10 devices · 3MW · Natural gas
Nigeria project
40 devices · 10MW · Natural gas
Shipping and Configuration
Liquid-cooling equipment is generally transported by sea freight. Contact MiningUS with the destination and site requirements to confirm configuration and shipping charges.
Want to Explore Similar Mining Options?
| Models | Coins | Meilleur Price | Hashrate | Power | Electricity | Algorithm | ROI | Profit |
|---|---|---|---|---|---|---|---|---|
| Antminer S21 XP Hydro | BCH, BSV, BTC | $6,140.00 | 473Th/s | 5670W | 11.99J/TH | SHA-256 | 18 Mon | $ 11.32 /day |
| Antminer S21+ Hydro | BCH, BSV, BTC | $2,195.00 – $2,645.00 | 358Th/s | 5370W | 15.00J/TH | SHA-256 | 10 Mon | $ 7.27 /day |
| Antminer S19 XP Hyd. | BCH, BSV, BTC | $1,284.00 | 257Th/s | 5304W | 20.64J/TH | SHA-256 | 12 Mon | $ 3.48 /day |
| Antminer S19e XP Hyd | BCH, BSV, BTC | $750.00 | 251Th/s | 5522W | 22.00J/TH | SHA-256 | 8 Mon | $ 2.99 /day |
Supplier-listed mining estimates at the time of update; profitability and prices change.
| Specification | AP-50Hyd — 96 slots, 500kW continuous generation |
|---|
Delivery costs shown before payment
Enter your complete delivery address at checkout to see available shipping services and charges. Shipping is separate from the product price unless expressly included. A missing rate does not mean free delivery.
Miners and spare parts
Confirmed in-stock items generally need 3–7 business days for preparation after cleared payment. Express transit is typically estimated at 5–10 business days after collection; the selected service and destination determine the actual estimate.
Cooling systems and heavy equipment
Containers, tanks, racks and other oversized equipment travel by suitable freight services. Delivery point, site access and unloading requirements must be confirmed. If no freight option is available at checkout, contact us before payment.
Customs and delivery support
Import duty, import taxes and brokerage are excluded unless the order explicitly confirms DDP or another duty-inclusive service. Tracking or waybill details are provided after dispatch. Inspect your delivery and contact us promptly about damage or missing items; an unboxing video is helpful but is not required for support.
Read the full shipping policy | Contact Mining US
Dispatch and transit estimates are separate and may be affected by customs, carrier disruption or public holidays. Applicable consumer rights remain unaffected.

Reviews