20-Slot 200kW Whatsminer 2U Modular Hydro Cooling Rack Plus

Scalable 200kW hydro cooling platform for 20 WhatsMiner 2U miners, with a separate CDU, customizable cooling equipment and support for multi-rack expansion.

Price on request. Contact MiningUS for a configuration and quote.

Need Customization?

After your configuration and order are confirmed, use our Order Customization page to submit your requirements.

Description

Scalable 200kW hydro cooling platform for 20 WhatsMiner units

Container Capacity
ASIC Miners
20 UNITS
Housed at full load
Total Power
200 kW
Continuous electrical load
Form Factor
Custom
Standard
Cooling
Hydro
Thermal management

Power Input 380V–415V AC 50/60Hz

Availability Typical lead time 15 days • DDP Sea Shipping Available

Compatible Models

View More ›

Supplier model and full-load estimates captured September 13, 2026. These figures change with market and operating conditions and are not guaranteed returns. Confirm exact miner compatibility and total operating load.

Product Description

The Plus rack provides a modular platform for 20 WhatsMiner 2U hydro miners and up to 200kW of miner load. Its separate miner cabinet and cooling-control assembly allow CDU sizing and heat rejection to follow the site’s actual requirements.

Start with a single installation and plan the CDU, main piping and power distribution for additional racks. The adjustable architecture supports staged growth and flexible placement of outdoor cooling equipment.

Core Advantages

01. Split Modular Hydro System

01. Split Modular Hydro System

Separate CDU and miner cabinets connect through quick couplings, allowing flexible layout and later expansion.

02. Color-Coded Water Piping

02. Color-Coded Water Piping

Red return and blue supply hoses make the coolant routes easy to identify during setup and maintenance.

03. Integrated Switch & Breakers

03. Integrated Switch & Breakers

A top-mounted network switch organizes cables, while individual breakers let one miner be serviced independently.

04. Stainless Steel Buffer Tank

The supplier describes a stainless-steel expansion tank that absorbs pressure variations, releases trapped air and supports automatic fluid replenishment.

05. Industrial PLC Touch Screen

05. Industrial PLC Touch Screen

The touch screen shows operating data. Language, parameters and control logic can be customized for site requirements.

06. Outdoor Heavy-Duty Dry Cooler

06. Outdoor Heavy-Duty Dry Cooler

The matched outdoor cooler uses large fans and cooling pads for heat rejection. Its specified cooling rating is 200kW at 35°C; performance depends on operating conditions.

Modular 1-to-N Infrastructure Scalability

The supplier describes expansion from 200kW to 1,000kW using multiple racks, a customized high-flow pump system and centralized power control. Plan CDU capacity, main pipework, monitoring and outdoor cooling for the intended expansion.

Modular hydro racks with centralized cooling connections

Full Specifications

Model AP-EM20 PLUS
Installed capacity 20 miners
Cooling rating 200kW at 35°C
Supplier-listed certification UL / CE
System composition 1 dry cooler + 1 miner cabinet + CDU & PLC + external piping
Auxiliary system energy consumption 10kW
Heat dissipation capacity (supplier-listed) >210kW
Environmental suitability −20°C to 45°C
Power input Three-phase 380–415V, 50Hz
Cabinet format 40U standard cabinet
Temperature control AC fan variable-frequency control + EC fan stepwise regulation
Pump 1 × 3kW
External miner cabinet dimensions 800 × 950 × 2160mm
Internal miner cabinet dimensions 750 × 900 × 2110mm
Miner cabinet weight 250kg
Control cabinet dimensions 600 × 1100 × 2160mm
Control cabinet weight 250kg
Dry cooler dimensions 2600 × 1850 × 2000mm
Dry cooler weight 800kg

The overview lists 50/60Hz, while the detailed table specifies 50Hz. The supplier lists both 200kW at 35°C and >210kW heat dissipation; confirm rating conditions and frequency in the quotation.

Certification Standards

The supplier states that its products meet leading international standards for safety, reliability, and performance.

China Classification Society

China Classification Society

Marine & offshore compliance

UL Listed

UL Listed

Safety tested & certified

CSA Certified

CSA Certified

North American compliance

CE Marking

CE Marking

European conformity

Complete Cooling Solutions

Model Cooling Capacity Miner Slots Dimensions (L × W × H) Application
12-Slot Integrated Whatsminer Hydro Cooling Rack 120kW 12 Slots 850 × 1000 × 2130mm Compact Home Deployments
20-Slot Whatsminer Hydro Cooling Rack 200kW 20 Slots 800 × 950 × 2160mm Customizable Modular Layouts
160-Slot Whatsminer Hydro Cooling Container 1.6MW 160 Slots 6058 × 2438 × 2896mm Industrial Mining Projects
240-Slot Whatsminer Hydro Cooling Container 2.4MW 240 Slots 13716 × 2438 × 2896mm Mega-Scale Industrial Facilities

Real Results from Real Miners

Deployment photographs and results reported by the supplier.

Supplier deployment example of centralized CDU and multiple racks

Denver, United States

1 × 800kW CDU to 4 Racks

Custom-sized CDUs support modular expansion.

+40% Space Optimization · −25% Capex Saved · $150K Annual Savings

Supplier deployment example with one rack and dry cooler

Kazakhstan

1 × 200kW CDU to 1 Rack

Modular integration for a smaller indoor installation.

+100% Clean Energy Uptime · −30% On-site Civil Costs · 99.9% System Reliability

The supplier attributes reduced equipment costs and expansion from one to four racks to its Denver installation. These are supplier-reported outcomes, not guaranteed results.

Supplier-reported global delivery: 1.2+ GW across 50+ countries and regions.

20-Slot Whatsminer 2U Modular Hydro Cooling Rack Plus FAQs

What is the main advantage of this modular rack compared with an integrated 200kW cooling rack?

A shared CDU can be sized for several racks, reducing duplicate cooling-control equipment and supporting future expansion.

Can one CDU support multiple 200kW cooling racks?

Yes. The supplier gives examples of a 400kW CDU serving two 200kW racks, or an 800kW CDU serving four. Size the complete loop to the project.

Can I start with one rack and expand the system later?

Yes. Start with one rack and reserve CDU, piping, electrical and outdoor cooling capacity for later stages.

Can one rack support 20 high-power or overclocked WhatsMiner Hydro miners?

Up to 20 compatible 2U Hydro miners can be installed if their combined operating load stays within 200kW and connections match the selected equipment.

How does a shared CDU maintain stable cooling across multiple racks?

The CDU is engineered for the connected rack count and load. Monitoring of coolant flow, pressure and temperature supports balanced circulation.

Can individual miners be powered down for maintenance without stopping the other miners?

Individual switches and circuit breakers allow a miner to be isolated for maintenance while unaffected positions continue operating.

Does a 200kW rack mean the site only needs 200kW of electrical capacity?

No. Allow for the supplier-listed 10kW auxiliary cooling load in addition to miner consumption, plus the electrical margin required by the final design.

When is this modular Plus architecture the better choice?

It suits multi-rack projects and sites expecting expansion, where centralized cooling can reduce repeated equipment and improve space use.

Additional information
SpecificationAP-EM20 PLUS — 20-slot 200kW modular hydro cooling system
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “20-Slot 200kW Whatsminer 2U Modular Hydro Cooling Rack Plus”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

Delivery costs shown before payment

Enter your complete delivery address at checkout to see available shipping services and charges. Shipping is separate from the product price unless expressly included. A missing rate does not mean free delivery.

Miners and spare parts

Confirmed in-stock items generally need 3–7 business days for preparation after cleared payment. Express transit is typically estimated at 5–10 business days after collection; the selected service and destination determine the actual estimate.

Cooling systems and heavy equipment

Containers, tanks, racks and other oversized equipment travel by suitable freight services. Delivery point, site access and unloading requirements must be confirmed. If no freight option is available at checkout, contact us before payment.

Customs and delivery support

Import duty, import taxes and brokerage are excluded unless the order explicitly confirms DDP or another duty-inclusive service. Tracking or waybill details are provided after dispatch. Inspect your delivery and contact us promptly about damage or missing items; an unboxing video is helpful but is not required for support.

Read the full shipping policy  |  Contact Mining US

Dispatch and transit estimates are separate and may be affected by customs, carrier disruption or public holidays. Applicable consumer rights remain unaffected.