2.4MW 240-Slot Avalon 2U Hydro Mining Container (40HQ)

Price range: $103,500.00 through $119,900.00

2.4MW 40HQ hydro cooling container for up to 240 Avalon A1566HA 2U miners. Integrated racks, CDU, power distribution and monitoring support large-scale deployments. Choose a Close Tower Solution or Dry Cooler Solution.

Need Customization?

Complete your order and payment first. Immediately after payment, visit our Order Customization page and submit the form with your customization requirements.

Description

2.4MW 240-Slot Avalon 2U Hydro Cooling Container for Enterprise Mining

Container capacity
ASIC miners
240 UNITS
Housed at full load
Total power
2,400 kW
Continuous electrical load
Form factor
Custom
Standard
Cooling
Hydro
Thermal management
Power input380V–415V AC 50/60Hz
AvailabilityTypical lead time 45 days • DDP Sea Shipping Available

⚙ Compatible Models

View More ›

Supplier reference estimates, not live or guaranteed earnings. Actual results vary with miner settings, network conditions, coin prices and electricity costs.

The supplier’s overview lists the models above, while its title and FAQ specify Avalon A1566HA and Avalon 2U hydro miners. Confirm compatibility for any alternative model before ordering.

Product Description

The AP-HC40-X240 brings 240 Avalon 2U hydro miner slots, pre-installed cabling and cooling infrastructure into one 40HQ container. Its nominal 2.4MW configuration is designed for large-scale mining operations.

Heavy-duty power cabinets, automatic reclosing breakers, lightning protection and dual-loop water circulation support continuous operation. Choose the closed-tower or dry-cooler configuration to suit the site.

Core Advantages

01. Datacenter-Style Layout

An accessible walkway supports inspections and maintenance in commercial hosting environments.

AP-HC40-X240 Datacenter-Style Layout

02. Integrated All-in-One System

Server racks, CDU, PDU cabinets and controls are consolidated in a single 40HQ container for efficient deployment.

AP-HC40-X240 Integrated All-in-One System

03. Advanced CDU System

Water pumps, a pressure tank and automatic refill piping provide coolant replenishment and pressure regulation.

AP-HC40-X240 Advanced CDU System

04. Individual Control Switches

Each rack slot has a labeled independent power switch and breaker for individual isolation and servicing.

AP-HC40-X240 Individual Control Switches

05. Instant Leak Detection

Floor-mounted moisture-sensing ropes trigger remote alarms and automatic power cutoffs when leaks are detected.

AP-HC40-X240 Instant Leak Detection

06. Water & Electricity Isolation

High-pressure water manifolds are physically separated from electrical cables and cabinets to reduce moisture-related risks.

AP-HC40-X240 Water & Electricity Isolation

Full Specifications

ModelAP-HC40-X240
Installed capacity240 seats
External dimensions (L × W × H)12192 × 2438 × 2896 mm
Internal dimensions (L × W × H)12000 × 2230 × 2660 mm
Weight7800 kg
Installed powerload2400 kW
Light-duty vertical multistage pump power30 kW
Fluid replenishing pump power0.2 kW
Total dry cooling tower fan power58.1 kW
Total closed cooling tower fan power22.5 kW
Total closed cooling tower spray pump power7.5 kW
System pipeline pressure0.2–0.4 MPa
System operating temperature range0–50°C
Coolant circulation demand per machine≥0.6 m³/h
Total circulating coolant demand≥2.5 m³
Molded Case Circuit Breaker125 A
Residual Current Circuit Breaker400 A
Contactor9 A
Intermediate relay24 V
CUL certified frequency converter380 V

Certification Standards

The supplier states that its products meet leading international standards for safety, reliability, and performance.

China Classification Society

China Classification Society

Marine & offshore compliance

UL Listed

UL Listed

Safety tested & certified

CSA Certified

CSA Certified

North American compliance

CE Marking

CE Marking

European conformity

Complete Cooling Solutions

Compare the supplier’s Avalon hydro cooling container range.

ModelCooling CapacityMiner SlotsDimensions (L × W × H)Application
100-Slot Avalon Hydro Cooling Container1 MW100 Slots6058 × 2438 × 2896 mmEntry-Level Mining Sites
120-Slot Avalon Hydro Cooling Container1.2 MW120 Slots6058 × 2438 × 2896 mmCommercial-Scale Operations
160-Slot Avalon Hydro Cooling Container1.6 MW160 Slots6058 × 2438 × 2896 mmIndustrial-Scale Projects
240-Slot Avalon Hydro Cooling Container2.1 MW (source comparison)240 Slots12192 × 2438 × 2896 mmMega-Scale Mining Facilities

The source comparison lists 2.1MW for the 240-slot model, while the product title and specification table list 2.4MW. Confirm the final rated cooling capacity for the selected solution.

Real Results from Real Miners

Supplier-reported deployment case studies and results.

Supplier deployment case study: Dallas, United States

Dallas, United States

2 × 2.4MW Hydro Project

Sustaining stable datacenter-grade hashing under heavy loads.

+32% Cooling Efficiency
-25% Cooling Power Draw
$1.5M Annual Savings

Supplier deployment case study: Kajaani, Finland

Kajaani, Finland

8 × 2.4MW Hydro Project

Achieving efficient grid deployments using clean hydropower.

+100% Operational Uptime
-30% Setup Time
99.9% System Reliability

The supplier reports 1.2+ GW cumulative delivered cooling capacity across 50+ countries and regions. These case-study results are supplier claims, not independently verified MiningUS customer results.

240-Slot Avalon Hydro Container FAQs

Which specific ASIC models are compatible?

The product title and supplier FAQ specify up to 240 Avalon A1566HA and standard Avalon 2U hydro miners with matching racks. The overview lists other brands; confirm the rack, electrical and cooling configuration before selecting an alternative model.

How does aisle containment improve cooling efficiency?

Metal isolation panels separate the hot and cold aisles to reduce hot-air recirculation under sustained load.

How are water and electricity isolated?

High-pressure manifolds are physically separated from electrical cabling and cabinets to reduce moisture exposure.

Is fire suppression included?

The supplier lists smoke detectors and thermal sensors, with an optional gas fire suppression system. Confirm the included scope in the selected configuration.

How does PLC control protect the 2.4MW load?

The PLC and HMI monitor coolant flow, temperature and pressure. Automated controls and reclosing circuit breakers respond to abnormal conditions and trigger shutdowns.

Additional information
SpecificationClose Tower Solution, Dry Cooler Solution
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “2.4MW 240-Slot Avalon 2U Hydro Mining Container (40HQ)”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

Delivery costs shown before payment

Enter your complete delivery address at checkout to see available shipping services and charges. Shipping is separate from the product price unless expressly included. A missing rate does not mean free delivery.

Miners and spare parts

Confirmed in-stock items generally need 3–7 business days for preparation after cleared payment. Express transit is typically estimated at 5–10 business days after collection; the selected service and destination determine the actual estimate.

Cooling systems and heavy equipment

Containers, tanks, racks and other oversized equipment travel by suitable freight services. Delivery point, site access and unloading requirements must be confirmed. If no freight option is available at checkout, contact us before payment.

Customs and delivery support

Import duty, import taxes and brokerage are excluded unless the order explicitly confirms DDP or another duty-inclusive service. Tracking or waybill details are provided after dispatch. Inspect your delivery and contact us promptly about damage or missing items; an unboxing video is helpful but is not required for support.

Read the full shipping policy  |  Contact Mining US

Dispatch and transit estimates are separate and may be affected by customs, carrier disruption or public holidays. Applicable consumer rights remain unaffected.