1.2MW 120-Slot Avalon 2U Hydro Mining Container (20HQ)
$55,000.00 – $65,000.00Price range: $55,000.00 through $65,000.00
This Avalon hydro cooling mining box is a 1.2MW hydro solution for Bitcoin mining, supporting up to 120 Avalon A1566HA 2U miners with efficient and reliable cooling.
Need Customization?
Complete your order and payment first. Immediately after payment, visit our Order Customization page and submit the form with your customization requirements.
120-Slot Flexible Modular Hydro Cooling Solution for Avalon 2U Series
⚙ Compatible Models
Product Description
Engineered for highly cost effective commercial deployments, the 1.2MW 120-Slot Avalon 2U Hydro Mining Container 20FT HQ delivers server class liquid cooling.
Custom tailored specifically for Canaan’s high performance Avalon 2U hydro miner series, this compact standard 20 foot container optimizes internal fluid dynamics to match their precise water block specifications. It integrates robust power distribution systems, high conductivity copper busbars, and large diameter stainless steel manifolds to ensure balanced, uniform water circulation across all 120 active slots.
This turnkey, plug and play solution allows operators to easily minimize onsite setup times, reduce energy overhead, and secure highly stable, reliable BTC mining performance globally.
Core Advantages
01. Integrated All-in-One System
Integrates the server racks, CDU, power cabinet, and control unit into a single 20FT container for rapid on-site setup, minimizing civil engineering costs and deployment time.
02. Color-Coded Rack Connections
Features rack-level breakers paired with clearly identified hot and cold coolant connections, creating a cleaner installation and making routine inspection and maintenance easier.
03. Heavy-Duty Power Cabinets
Industrial power cabinets provide independent circuit protection, operating status indicators, and reliable overload protection for high-density hydro-cooled mining deployments.
04. Leak Detection System
High-sensitivity moisture detection continuously monitors critical areas for coolant leakage and helps operators respond quickly before a small leak can affect valuable mining hardware.
05. Premium Engineering Details
Standard 2U server-grade racks, organized cabling, durable connectors, and high-quality fluid-distribution components provide a stable foundation for continuous mining operation.
06. Intelligent Management System
PLC-based intelligent controls monitor circulation pumps, coolant temperature, pressure, flow, cooling equipment, and other operating conditions for centralized system management.
Full Specifications
| Model | AP-HC20-X120 | Installed capacity | 120 Seat |
| Installed powerload | 1200 kW | Power of the light-duty vertical multistage pump | 15 kW |
| Power of the fluid replenishing pump | 0.2 kW | Total power of the dry cooling tower fan | 33.2 kW |
| Total power of the closed cooling tower fan | 13.2 kW | Total power of the closed cooling tower spray pump | 3 kW |
| System pipeline pressure | 0.2–0.4 MPa | Operating temperature range of the system | 0–50 °C |
| Coolant circulation demand of a single machine | ≥0.5 m³/h | Total demand for circulating coolant within the system | ≥1.2 m³ |
| Molded Case Circuit Breaker | 125 A | Residual Current Circuit Breaker | 400 A |
| Contactor | 9 A | Intermediate relay | 24 V |
| CUL certified frequency converter | 380 V |
Certification Standards
Our products meet leading international standards for safety, reliability, and performance.
Complete Cooling Solutions
We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.
|
100-Slot Avalon Hydro Cooling Container
|
Compare
120-Slot Avalon Hydro Cooling Container
|
160-Slot Avalon Hydro Cooling Container
|
240-Slot Avalon Hydro Cooling Container
|
|
|---|---|---|---|---|
| ❄ Cooling Capacity | 1 MW | 1.2 MW | 1.6 MW | 2.4 MW |
| ⚙ Miner Slots | 100 Slots | 120 Slots | 160 Slots | 240 Slots |
| 📏 Dimensions (L × W × H) | 6,058 × 2,438 × 2,896 mm | 6,058 × 2,438 × 2,896 mm | 6,058 × 2,438 × 2,896 mm | 12,192 × 2,438 × 2,896 mm |
| ▣ Application | Entry-Level Mining Sites | Commercial-Scale Operations | Industrial-Scale Projects | Mega-Scale Mining Facilities |
| Read More → | Read More → | Read More → |
Real Results from Real Miners
View All ››2 × 1.2MW Hydro Project
Recycling continuous miner thermal heat for commercial greenhouse heating operations.
6 × 1.2MW Hydro Project
Supplying recycled high-temperature water for municipal district-heating infrastructure.
Integrating this 120-slot container into our Manitoba greenhouse was a massive success. It recycled nearly 100% of mining heat to warm our tomatoes, dramatically reducing our annual boiler heating bills.
Manitoba, Canada
120-Slot Avalon Hydro Container FAQs
This container is optimized specifically for Canaan's high-efficiency hydro miners, supporting up to 120 units of the Avalon A1566HA and compatible Avalon 2U hydro series with matching rack dimensions, coolant interfaces, and electrical requirements.
For sub-zero winter operation, the system supports coolant configurations suitable for low-temperature environments and controlled circulation through the external cooling loop.
Appropriate glycol concentration, insulation, circulation control, and operating procedures help prevent freezing while maintaining stable heat rejection and miner operation.
Yes. This system can be integrated with heat-recovery applications that reuse mining-generated thermal energy instead of rejecting all of it to the atmosphere.
Depending on miner load, coolant temperatures, heat exchanger design, and the receiving heating system, a large proportion of the mining heat can be recovered for applications such as greenhouse heating, hot water, or district heating.
The system is built around standard container dimensions for practical international transportation and is shipped with the major internal mining, cooling, and electrical infrastructure preassembled.
On arrival, the site primarily needs to complete the required external power, cooling, network, and commissioning connections, significantly reducing on-site assembly work.
Water filters should be inspected regularly and cleaned according to coolant quality, operating hours, flow conditions, and the amount of contamination present in the system.
Plate heat exchangers should also be inspected periodically for scaling or restricted flow. Regular maintenance helps prevent pipeline blockage, maintain stable circulation, and preserve efficient heat transfer.
| Specification | Close Tower Solution, Dry Cooler Solution |
|---|
Delivery costs shown before payment
Enter your complete delivery address at checkout to see available shipping services and charges. Shipping is separate from the product price unless expressly included. A missing rate does not mean free delivery.
Miners and spare parts
Confirmed in-stock items generally need 3–7 business days for preparation after cleared payment. Express transit is typically estimated at 5–10 business days after collection; the selected service and destination determine the actual estimate.
Cooling systems and heavy equipment
Containers, tanks, racks and other oversized equipment travel by suitable freight services. Delivery point, site access and unloading requirements must be confirmed. If no freight option is available at checkout, contact us before payment.
Customs and delivery support
Import duty, import taxes and brokerage are excluded unless the order explicitly confirms DDP or another duty-inclusive service. Tracking or waybill details are provided after dispatch. Inspect your delivery and contact us promptly about damage or missing items; an unboxing video is helpful but is not required for support.
Read the full shipping policy | Contact Mining US
Dispatch and transit estimates are separate and may be affected by customs, carrier disruption or public holidays. Applicable consumer rights remain unaffected.

Reviews
There are no reviews yet.