110-Slot 620kW Antminer Liquid Cooling Rack
$19,999.00 Original price was: $19,999.00.$15,999.00Current price is: $15,999.00.
This high-density Antminer liquid cooling rack is designed for indoor deployment, supporting 110 Antminer Hydro miners with a 620kW cooling capacity.
Need Customization?
Complete your order and payment first. Immediately after payment, visit our Order Customization page and submit the form with your customization requirements.
620kW 110-Slot Antminer Liquid Cooling Rack for Indoor Mining
⚙ Compatible Models
Product Description
Designed for flexible indoor and warehouse setups, the 620kW 110-Slot Antminer Liquid Cooling Rack offers a compact, integrated liquid cooling solution without requiring a large shipping container.
Specially built to fit standard Antminer liquid series miners, this compact rack frame integrates easily into existing rooms, factory floors, or warehouses. It features industrial water manifolds and reliable power distribution with independent breakers to ensure stable, consistent water pressure and electrical safety across all 110 active slots.
This space saving layout allows you to easily add more racks as your business and budget grows, ensuring stable, highly reliable mining performance.
01. Integrated Open-Frame System
Features a compact, open-rack layout that integrates the server shelves, built-in CDU, power cabinet, and control console for fast, space-saving indoor site deployments.
02. Premium Connector Fittings
Utilizes high-quality factory-original quick-connect fittings and durable water hoses, ensuring stable, leak-free fluid distribution to each individual miner during daily operations.
03. Leak-Proof CDU Piping
Features seamless, single-piece stainless-steel manifolds for the CDU system, eliminating welded-joint leak risks and supporting secure, reliable coolant circulation.
04. Yellow Leakage Sensing
Integrates floor-mounted, highly visible yellow moisture-sensing ropes at the base of the rack frame to instantly detect coolant leaks and protect valuable mining hardware.
05. UL-Certified Power Cabinet
Houses an industrial power cabinet designed around UL-certified components, including robust circuit breakers and electrical safety hardware for secure and stable power distribution.
06. Intelligent Management System
Tracks real-time voltage, pump VFD frequencies, system status, and historical alarms through the touchscreen, helping operators diagnose faults and manage overall power draw safely.
| Model | AP-A110 | Installed capacity | 110 Seat |
| Installed powerload | 605 KW | Power of the light-duty vertical multistage pump | 11 KW |
| Power of the fluid replenishing pump | 0.2 KW | Total power of the dry cooling tower fan | 24.9 KW |
| Total power of the closed cooling tower fan | 8.8 KW | Total power of the closed cooling tower spray pump | 2.2 KW |
| System pipeline pressure | 0.2-0.4 MPA | Operating temperature range of the system | 22-42 ℃ |
| Coolant circulation demand of a single machine | ≥0.5 m³/h | Total demand for circulating coolant within the system | ≥12 m³ |
| Molded Case Circuit Breaker | -- | Residual Current Circuit Breaker | 400 A |
| Contactor | 9 A | Intermediate relay | 24 V |
| CUL certified frequency converter | 380 V |
Certification Standards
Our products meet leading international standards for safety, reliability, and performance.
Complete Cooling Solutions
We design and manufacture a complete range of hydro cooling solutions for every scale, from hydro cooling cabinets and containers to CDUs and dry coolers.
|
28-Slot Antminer Hydro Cooling Rack
|
Compare
110-Slot Antminer Hydro Cooling Rack
|
154-Slot Antminer Hydro Cooling Rack
|
240-Slot Antminer Hydro Cooling Rack
|
|
|---|---|---|---|---|
| ❄ Cooling Capacity | 154 kW | 620 kW | 870 kW | 1350 kW |
| ⚙ Miner Slots | 28 Slots | 110 Slots | 154 Slots | 240 Slots |
| 📏 Dimensions (L × W × H) | 1,000 × 1,000 × 2,000 mm | 4,880 × 1,300 × 2,700 mm | 4,880 × 1,500 × 2,700 mm | 6,025 × 1,500 × 2,700 mm |
| ▣ Application | Customizable Modular Expansion | Standard Warehouse Deployments | High-Density Industrial Projects | Mega-Scale Warehouse Facilities |
| Read More → | Read More → | Read More → |
110-Slot Antminer Hydro Cooling Rack FAQs
It is designed for small to mid-scale commercial operators, startup miners, or hosting providers who require professional water-cooling capabilities but prefer to start with a highly flexible, lower-CapEx, and easily manageable indoor setup rather than purchasing large shipping containers.
This rack is especially suited for indoor warehouse deployments and existing industrial buildings with standard power access.
It allows operators to build high-density hydro mining setups without container infrastructure, significantly lowering initial investment costs while maximizing the reuse of existing facility structures.
The internal water circulation system requires an initial filling volume of at least one point two cubic meters of purified deionized water.
Maintaining conductivity strictly below ten micro siemens helps prevent pipeline scaling and protects the water blocks of all active server slots.
Yes. When paired with our high-efficiency dry cooling tower featuring a twenty four point nine kilowatt fan system, the rack operates on a completely closed loop with zero water consumption.
This makes it ideal for water-restricted indoor or warehouse operations.
The integrated power cabinet is engineered for standard 380V outputs with a 400A residual current circuit breaker.
This high-spec electrical infrastructure provides robust overcurrent protection, allowing operators to fully adapt the system to local electrical grid requirements.
Delivery costs shown before payment
Enter your complete delivery address at checkout to see available shipping services and charges. Shipping is separate from the product price unless expressly included. A missing rate does not mean free delivery.
Miners and spare parts
Confirmed in-stock items generally need 3–7 business days for preparation after cleared payment. Express transit is typically estimated at 5–10 business days after collection; the selected service and destination determine the actual estimate.
Cooling systems and heavy equipment
Containers, tanks, racks and other oversized equipment travel by suitable freight services. Delivery point, site access and unloading requirements must be confirmed. If no freight option is available at checkout, contact us before payment.
Customs and delivery support
Import duty, import taxes and brokerage are excluded unless the order explicitly confirms DDP or another duty-inclusive service. Tracking or waybill details are provided after dispatch. Inspect your delivery and contact us promptly about damage or missing items; an unboxing video is helpful but is not required for support.
Read the full shipping policy | Contact Mining US
Dispatch and transit estimates are separate and may be affected by customs, carrier disruption or public holidays. Applicable consumer rights remain unaffected.

Reviews