MiningUS AP-H6 hydro cooling cabinet and dry cooler
6-Slot 33kW Antminer Hydro Cooling Rack Price range: $1,500.00 through $3,100.00
Back to products
12KW Water Cooling Coolant
12KW Water Cooling Coolant Original price was: $65.00.Current price is: $50.00.

20-Slot 200kW Whatsminer 2U Integrated Hydro Cooling Rack

Price range: $11,820.00 through $12,800.00

200kW integrated hydro cooling rack for up to 20 WhatsMiner M53, M63 or M73 series 2U miners. Choose a cabinet with a closed cooling tower or dry cooler, with individual miner controls, integrated CDU and PLC monitoring.

Need Customization?

Complete your order and payment first. Then visit our Order Customization page and submit your requirements.

Description

Integrated 200kW deployment for 20 WhatsMiner 2U hydro miners

CONTAINER CAPACITY

ASIC MINERS20 UNITSHoused at full load
TOTAL POWER200 kWContinuous electrical load
FORM FACTORCustomStandard
COOLINGHydroThermal management

Power Input 380V–415V AC 50/60Hz

Availability Typical lead time 15 days • DDP Sea Shipping Available

Compatible Models

The supplier’s overview heading incorrectly says 200+ miners; this product’s confirmed capacity is 20. Its compatibility widget reports zero slots, so the copied zero-slot and $0.00/day figures below are display errors, not usable capacity or return estimates. Confirm the exact miner version before ordering.

View More ›

Product Description

This integrated rack combines installation space for 20 WhatsMiner 2U hydro miners with a 200kW cooling and heat-management system. It supports M53, M63 and M73 series deployments, with Cabinet+Closed Tower and Cabinet+Dry Cooler configurations.

The cabinet brings power distribution, coolant circulation and controls into one organized assembly. Factory-prepared connections reduce field installation work, while individual miner controls simplify routine service. It is designed for warehouses and indoor mining locations with appropriate space, power and outdoor heat rejection.

Core Advantages

01. Specialized 2U Slots & Manifolds

01. Specialized 2U Slots & Manifolds

Twenty dedicated 2U positions have individual coolant connection points and a manifold arrangement for liquid distribution.

02. Organized Power Cabinet Wiring

02. Organized Power Cabinet Wiring

Clearly organized wiring supports troubleshooting and maintenance. The supplier describes the components as UL compliant; confirm documentation for the ordered configuration.

03. Independent Switch for Each Slot

03. Independent Switch for Each Slot

Each miner has its own switch and breaker, allowing individual isolation for service without stopping unaffected miners.

04. Leak Detection

04. Leak Detection

A moisture-sensing rope along the cabinet floor raises an alert when coolant is detected.

05. Complete CDU System

05. Complete CDU System

The pump, expansion tank and heat exchanger manage circulation and transfer the miner heat load to the external cooling equipment.

06. Customizable PLC Control

06. Customizable PLC Control

The HMI displays pressure and temperature readings. PLC monitoring and control can be configured for the site.

Full Specifications

Model AP-M20
Installed miner capacity 20 WhatsMiner 2U hydro miners
Installed power load 200kW
External dimensions (L × W × H) 1460 × 1000 × 2200mm
Internal dimensions (L × W × H) 1410 × 950 × 2150mm
Weight 500kg
Vertical multistage pump power 4kW
Fluid replenishing pump power 0.2kW
Dry cooler fan total power 8.3kW
Closed cooling tower fan total power 3kW
Closed cooling tower spray pump total power 1.1kW
System pipeline pressure 0.2–0.4MPa
System operating temperature range 0–50°C
Coolant circulation per miner ≥0.6m³/h
Total circulating coolant volume ≥0.25m³
Residual current circuit breaker 400A
Contactor 9A
Intermediate relay 24V
CUL certified frequency converter (supplier-listed) 380V

Plug & Play with Cooling System

Dry cooler and closed cooling tower connection layouts

Certification Standards

The supplier states that its products meet leading international standards for safety, reliability, and performance.

China Classification SocietyChina Classification Society

Marine & offshore compliance

UL ListedUL Listed

Safety tested & certified

CSA CertifiedCSA Certified

North American compliance

CE MarkingCE Marking

European conformity

Complete Cooling Solutions

Compare the supplier’s WhatsMiner hydro cooling options for different deployment scales.

Model ❄ Cooling Capacity ⚙ Miner Slots Dimensions (L × W × H) Application
12-Slot Integrated Whatsminer Hydro Cooling Rack 120kW 12 Slots 850 × 1,000 × 2,130mm Home & Professional Offices
20-Slot Integrated Whatsminer Hydro Cooling Rack 200kW 20 Slots 1,460 × 1,000 × 2,200mm Mid-Sized Mining Clusters
160-Slot Whatsminer Hydro Cooling Container 1.6MW 160 Slots 6,058 × 2,438 × 2,896mm Industrial Scale Facilities
240-Slot Whatsminer Hydro Cooling Container 2.4MW 240 Slots 13,716 × 2,438 × 2,896mm Enterprise Mega Infrastructure

Supplier dimension punctuation “8,50” and “1,3716” has been normalized to 850 and 13,716mm. Confirm final dimensions in the order specification.

20-Slot Whatsminer Integrated Hydro Cooling Rack FAQs

Can this rack support 20 overclocked WhatsMiner Hydro miners?

The supplier specifies up to 200kW total miner load for compatible M53, M63 and M73 Hydro units, including high-performance operation at approximately 10kW per unit. Match the exact miner version and operating mode to the electrical and cooling design.

Does the 200kW rating mean every miner slot is limited to 10kW?

200kW is the total rack load, not a fixed limit for each position. Different compatible models and modes can share a rack if their combined load stays within the system rating and each connection is suitably rated.

How does the system maintain enough coolant flow for all 20 miners?

The supplier lists 13m³/h rated circulation and a minimum of 0.6m³/h per miner, or approximately 12m³/h for 20 units. An automatic pressure-regulating pump and PLC constant-flow control manage circulation.

Will a problem with one miner affect the entire 20-miner rack?

Individual switches and breakers let one miner be isolated for inspection or service while other miners continue operating. Shared cooling or electrical faults can still require a wider shutdown.

What happens if coolant temperature, flow, pressure, or network conditions become abnormal?

PLC monitoring tracks power, temperature, flow, pressure and network conditions around the clock. Operators can identify abnormal readings centrally and respond to the affected equipment.

How much on-site piping work is required during installation?

Factory-prepared piping, valves, power components and quick-connect interfaces reduce field assembly. Compatible miners connect to the supply and return lines; the site still needs suitable electrical service and connections to the selected heat-rejection equipment.

For a 200kW rack, should I use a dry cooler or a closed cooling tower?

The supplier recommends considering a matched dry cooler where low water consumption and reduced water-system maintenance are priorities. A closed cooling tower may suit hotter climates or larger sites where evaporative heat rejection is useful. Size either option for local conditions.

Can I expand from one 200kW rack to a 1MW mining deployment?

Five 200kW racks provide approximately 1MW of installed miner capacity. Reserve electrical supply, main piping, outdoor cooling, installation space and monitoring interfaces when planning phased expansion.

Additional information
SpecificationCabinet+Closed Tower, Cabinet+Dry Cooler
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “20-Slot 200kW Whatsminer 2U Integrated Hydro Cooling Rack”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

Delivery costs shown before payment

Enter your complete delivery address at checkout to see available shipping services and charges. Shipping is separate from the product price unless expressly included. A missing rate does not mean free delivery.

Miners and spare parts

Confirmed in-stock items generally need 3–7 business days for preparation after cleared payment. Express transit is typically estimated at 5–10 business days after collection; the selected service and destination determine the actual estimate.

Cooling systems and heavy equipment

Containers, tanks, racks and other oversized equipment travel by suitable freight services. Delivery point, site access and unloading requirements must be confirmed. If no freight option is available at checkout, contact us before payment.

Customs and delivery support

Import duty, import taxes and brokerage are excluded unless the order explicitly confirms DDP or another duty-inclusive service. Tracking or waybill details are provided after dispatch. Inspect your delivery and contact us promptly about damage or missing items; an unboxing video is helpful but is not required for support.

Read the full shipping policy  |  Contact Mining US

Dispatch and transit estimates are separate and may be affected by customs, carrier disruption or public holidays. Applicable consumer rights remain unaffected.