Bitmain ANTRACK V2 24kW For 4 Units Hydro Cooling Solution

$8,888.00

ANTRACK V2 is a split-type 24 kW hydro cooling system supporting up to four conventional or 2U hydro miners, or two 3U miners, with heat recovery for heating and hot-water applications up to 80°C.

Description

Modular 24kW Hydro Cooling with 80°C Heat Recovery

ASIC miners

4 units

Total power

24 kW

Form factor

Custom

Cooling

Hydro

Power input: 380–415 V AC. See the separate cabinet and cooler frequency ratings below.

Compatible Models

Model Hashrate / Efficiency Slots Full-load estimate
Antminer S19 XP Hyd. 257Th/s · 20.6 J/Th 4 $39.20/day
Antminer S19 Pro+ Hyd. 198Th/s · 27.5 J/Th 4 $30.20/day
Antminer S19 XP Hyd 3U 512Th/s · 20.7 J/Th 2 $39.04/day
Antminer S19 XP+ Hyd 293Th/s · 19 J/Th 4 $44.68/day
Antminer S19e XP Hyd 251Th/s · 22 J/Th 4 $38.28/day
Antminer S21 Hyd 335Th/s · 16 J/Th 4 $51.08/day
Antminer S21 XP+ Hyd 500Th/s · 11 J/Th 4 $76.24/day
Antminer S21+ Hydro 358Th/s · 15 J/Th 4 $54.60/day
Antminer S21e Hydro 310Th/s · 17 J/Th 4 $47.28/day
Antminer S21e XP Hyd 3U 860Th/s · 13 J/Th 2 $65.56/day
Antminer S21e XP Hyd 430Th/s · 13 J/Th 4 $65.56/day
Antminer S21j XP Hyd 495Th/s · 12 J/Th 4 $75.48/day
Antminer S23 Hyd 3U 1160Th/s · 9.5 J/Th 2 $88.44/day
Antminer S23e Hyd 2U 865Th/s · 10 J/Th 2 $65.94/day

Supplier compatibility and revenue estimates; combined miner load must remain within 24 kW. Actual revenue changes with mining conditions.

24 kW Heat Recovery Solution

The ANTRACK V2 combines a compact hydro-mining cabinet with an external heat-pump unit. It can use mining heat for space heating, radiators, underfloor circuits, hot water, greenhouses or pools, with a listed heating-water outlet temperature up to 80°C.

The two-tier cabinet accommodates up to four conventional hydro or 2U miners, or two 3U miners. Mixed arrangements are possible within the 24 kW thermal limit. Miner compatibility, electrical supply and heating-loop requirements should be checked for the installation.

Surplus Power Applications

The supplier describes deployments using spare hydropower, solar or wind output, biogas or biomass generation, and industrial on-site power. Its example pairs four miners totaling 1,172 TH/s with 24 kW of surplus electricity.

The supplier estimates approximately 0.212 BTC annually under its example conditions: about $13,335 at a $62,767 BTC reference price, $26,813 at $126,211, or $42,490 at $200,000. These illustrative revenues exclude pool fees, maintenance and installation and are not a forecast or a return guarantee. Mining equipment shown in examples does not establish the contents of this listing.

Cabinet Specifications

Model ANTRACK V2-EC4-DTHP
Installed capacity 4 hydro miners / 4 × 2U hydro miners / 2 × 3U hydro miners
Heat dissipation capacity 24 kW
Dimensions, unpacked (L × W × H) 1,200 × 600 × 1,300 mm
Dimensions, packaged 1,460 × 780 × 1,330 mm
Listed cabinet weight 210 kg
AC input voltage 380–415 V
Cabinet frequency 60 Hz (detailed source specification)
Input current 63 A
Rated cabinet power 450 W
Noise 60 dBA at 1 m
Pump lift 19 m
Water connector diameter DN20

The supplier overview lists 50/60 Hz, while its detailed cabinet table specifies 60 Hz. Confirm the cabinet frequency for your supply before installation.

External Cooler Specifications

Dimensions, unpacked (L × W × H) 1,340 × 570 × 1,330 mm
Dimensions, packaged 1,490 × 590 × 1,495 mm
Net / gross weight 235 / 248 kg
AC input voltage 380–415 V
Frequency 50–60 Hz
Maximum input current 21 A
Typical heating capacity 32 kW
Typical compressor input 8 kW
Typical EER 3.0
Sound level 50 dB(A)
Refrigerant R290
Heating water outlet temperature 80°C

Real-World Hydronic Heating Solutions

The supplier describes a project in Martinville, Canada, delivering 54–80°C water to building heating circuits, with a projected reduction of nearly 50% in community heating bills. It also describes reusing surplus electricity at a UK hydro station. These are supplier-reported applications and projections.

Complete Cooling Solutions

Cooling rack Capacity Slots Dimensions (L × W × H) Application
4-Slot Antminer Hydro Cooling Rack 24 kW 4 1,200 × 600 × 1,300 mm Home setup & heat recycling
6-Slot Antminer Hydro Cooling Rack 35 kW 6 800 × 800 × 1,450 mm Standard workshop mining
9-Slot Antminer Hydro Cooling Rack 50 kW 9 800 × 800 × 1,600 mm Professional home facilities
12-Slot Antminer Hydro Cooling Rack 70 kW 12 700 × 800 × 1,800 mm High-capacity residential mining

Real Results from Real Miners

The following project descriptions, photographs and performance figures are supplied by the manufacturer’s distributor.

Zurich, Switzerland — 4 × 24kW Small Facility Project

Supplier ANTRACK V2 workshop deployment in Zurich

A workshop deployment combining conventional Antminer hydro units and 3U miners. Supplier-reported figures: +100% heat reuse, −42 dB noise reduction, and $0 extra heating fuel.

Salt Lake City, United States — 2 × 24kW Home Heating Project

Supplier ANTRACK V2 home-heating deployment

The supplier describes two units supporting residential underfloor heating. Reported figures: −28% payback period, −35% energy expenses, and 99.9% thermal stability. These project-specific claims are not independently verified MiningUS results.

Additional information
Cooling capacity24 kW
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Bitmain ANTRACK V2 24kW For 4 Units Hydro Cooling Solution”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

Delivery costs shown before payment

Enter your complete delivery address at checkout to see available shipping services and charges. Shipping is separate from the product price unless expressly included. A missing rate does not mean free delivery.

Miners and spare parts

Confirmed in-stock items generally need 3–7 business days for preparation after cleared payment. Express transit is typically estimated at 5–10 business days after collection; the selected service and destination determine the actual estimate.

Cooling systems and heavy equipment

Containers, tanks, racks and other oversized equipment travel by suitable freight services. Delivery point, site access and unloading requirements must be confirmed. If no freight option is available at checkout, contact us before payment.

Customs and delivery support

Import duty, import taxes and brokerage are excluded unless the order explicitly confirms DDP or another duty-inclusive service. Tracking or waybill details are provided after dispatch. Inspect your delivery and contact us promptly about damage or missing items; an unboxing video is helpful but is not required for support.

Read the full shipping policy  |  Contact Mining US

Dispatch and transit estimates are separate and may be affected by customs, carrier disruption or public holidays. Applicable consumer rights remain unaffected.